1, Excellent fire performance, fire rating not only mee […]

1, Excellent fire performance, fire rating not only meet the international GB12666.6A class 950 ℃ 90min can also meet the requirements of the British BS6387-1994 A-class 650 ℃ 3h B-class 750 ℃ 3h C-class 950 ℃ 3h requirements while also burning in the fire Water spray and mechanical impact.
2, The length of a long Whether it is single or multi-core cable length to meet the needs of power supply length limit up to 2000m.
3, Section of large single core cable cross-section up to 1000mm2 multi-core cable cross-section up to 240mm2.
4, With flexibility, the cable can be placed in the cable tray, the bending radius ≥ 20D, D is the cable diameter.
5, Smoke-free combustion, non-toxic insulation material "does not burn the body," burning does not produce any harmful gases, but will not occur secondary pollution, be called green products.
6, Cross-section capacity is too large, not only the cross-section cable flow and has a large overload capacity. According to the wiring requirements Usually the cable surface temperature ≤ 70 ℃? If the wiring can not be touched? Does not come into contact with combustible building materials? Cable sheath temperature up to 105 ℃. Overload fireproof cable allows the working temperature up to 250 ℃.
7, Corrosion-resistant, organic insulation and fire-resistant cables sometimes need to wear plastic pipe or iron pipe, plastic is easy to aging brittle, iron pipe easy to rust; fire cable is copper sheath without wear tube, copper sheath corrosion resistance.
8, No electromagnetic interference, fire cables and signal, control and other wire and cable laying in the same shaft when the fireproof cable shield in the copper jacket will not interfere with the signal? Control wire and cable transmission of information.
9, Good safety, fire cables in addition to the normal power supply in the flame, start fire-fighting equipment to reduce fire losses. At the same time on personal safety is also particularly reliable, the copper sheath is a good conductor, is the best grounding wire, and continuous to the cable length, greatly improving the sensitivity and reliability of ground protection.
10, Long service life, inorganic insulating materials, high temperature, and not easy to aging, his life than the organic insulated cables increased many times in normal working conditions, its life can be equivalent to the building.
11, Flexible fire cable transport and installation, including installation